AeternaEnergy Group

E-000 Aeterna Energy Group · Las Vegas, Nevada

Own
your power.

Energy systems designed in direct current — for homes, buildings and the structures beyond the grid.

We design, engineer and program DC-first solar, battery storage and power distribution. Then we keep it running. The goal is to take each property as far off the grid as it can sensibly go, and to retire the standby generator for good.

Architecture
DC-first · one shared bus
Storage
Battery-centered
Generator
Optional → retired
Coverage
All 50 states · HQ NV

E-101 What we do

Designer. Engineer.
Controls provider.

One firm accountable for the system, from the first site study to every year it runs.

  1. 01

    Design & Engineering

    Site study, load analysis and a DC-first system architecture for the property. Permit drawings, with PE-sealed drawings where the jurisdiction requires them.

    SITE STUDY · ARCHITECTURE · DRAWINGS
  2. 02

    Equipment

    Complete system packages: solar PV, battery storage, DC/DC charge modules, DC power distribution, bidirectional DC-to-AC inverters and the controller that runs them. Listed equipment only.

    PV · STORAGE · DC DISTRIBUTION · INVERTERS
  3. 03

    Installation Coordination

    In Nevada, our own licensed electricians install. Everywhere else we coordinate a licensed partner installer, or support the installer you choose, with kits, labeled harnesses and clear documentation.

    NV CREWS · PARTNERS · YOUR INSTALLER
  4. 04

    Programming & Controls

    The Aeterna EMS is configured for each site and its utility's rules: bus start-up sequencing, state-of-charge management, load shedding, tariff-aware peak control and remote commissioning.

    EMS · TARIFF LOGIC · COMMISSIONING
  5. 05

    Monitoring & Service

    Remote monitoring, alerts, firmware and performance reporting, plus maintenance plans with inspections and battery health testing. Field visits are handled by Aeterna technicians or certified partners.

    MONITORING · ALERTS · MAINTENANCE
  6. “Whoever installs it, wherever it sits, every system runs on one architecture, one controls platform and one service organization.”

    THE AETERNA STANDARD

E-201 The DC-first approach

Stay in DC.
Convert only when you must.

A proprietary architecture, designed in-house.

Solar panels and batteries are DC devices, and so is much of what a modern building runs on. Conventional systems convert back and forth between DC and AC at almost every step. Aeterna ties generation, storage and DC-capable loads to one common DC bus, run by the Aeterna EMS, and converts to AC only for the circuits that still need it.

ONE-LINE · MODE
Aeterna DC-first one-line diagram Solar feeds a shared DC bus through a DC/DC charge module. A battery, DC loads and protected critical loads connect to the same bus. A bidirectional inverter converts to AC for the existing AC panel. The grid and generator are optional connections. SHEET E-201 · DC-FIRST ONE-LINE · AETERNA PROPRIETARY DESIGN NOT FOR CONSTRUCTION · ILLUSTRATIVE AETERNA EMS CONTROL · MONITOR SOLAR PV ROOF · CARPORT · GROUND DC/DC MPPT CHARGE DC ⇄ AC BIDIRECTIONAL AC PANEL EXISTING CIRCUITS UTILITY GRID OPTIONAL GENERATOR RETIRED / LAST RESORT COMMON DC BUS LFP STORAGE · CHARGING DC LOADS LIGHTING · DRIVES IT · CONTROLS CRITICAL LOADS DC-FED · PROTECTED NO TRANSFER GAP

E-251 How it works

Follow the power,
end to end.

Five steps from sunlight to the lights staying on.

Solar on the roof feeds a DC power cabinet and its common DC bus. The battery bank, DC loads and protected critical loads share that bus, and a bidirectional inverter serves the existing AC panel. The utility connection is optional. Follow the numbered steps, switch modes to see how the power path changes, and drag to look around.

3D MODEL · MODE
Illustrative 3D model of a home with solar on the roof, a DC power cabinet with a common DC bus, a battery bank, a bidirectional inverter feeding the AC panel, DC loads, critical loads and an optional utility connection, with gold lines showing the power path.

E-301 Applications

Homes. Buildings.
Structures.

One value proposition at every scale: own your power.

RESIDENTIAL

Homes & estates

Whole-home battery backup without a generator, lower bills and peak control. For new builds, a full DC-first design with a DC sub-panel. For existing solar owners, storage and controls added to what you have.

  • Resilience Core
  • DC Solar + Storage
  • Aeterna Off-Grid Estate

COMMERCIAL · MULTIFAMILY

Buildings & portfolios

A DC microgrid on a 380 VDC-class bus for demand-charge management, tenant resilience and uptime, with a multi-site dashboard and one engineering standard across every property in every state.

  • Commercial / Multifamily DC Microgrid
  • Aeterna Controls multi-site
  • Commercial O&M

REMOTE · OFF-GRID

Structures beyond the grid

Ranches, agricultural sites, cabins, telecom and construction sites, anywhere utility service is unavailable or a line extension costs too much. Skid- or container-based power, engineered to run on its own.

  • Remote Structure Power Kit
  • Aeterna Off-Grid Estate

E-401 Generator replacement

Silent backup.
No fuel. No start-up.

Where full independence isn't practical, the battery replaces the generator.

A fossil-fuel standby generator waits for the power to fail, then starts, then transfers. An Aeterna system is already running. Protected circuits are fed from the DC bus, so when the grid drops, they don't notice.

FactorStandby generatorAeterna battery
FuelGas, propane or dieselSun and storage
On outageStart, then transferAlready online
Critical loadsBrief interruptionNo transfer gap
Noise & exhaustEngine running on siteSilent · none on site
Every other daySits idleSolar storage, peak control
OversightPeriodic exercise runsMonitored remotely, continuously

E-501 Off-grid

As far off the grid
as it can sensibly go.

Independence is a spectrum. We engineer each property to the right point on it.

The grid becomes optional

Solar and storage on a shared DC bus carry the property day to day. The EMS uses the grid only when it makes sense under the local tariff, and islands automatically when it fails.

GRID: OPTIONAL · STORAGE: PRIMARY · GENERATOR: NOT REQUIRED

E-601 Process

From site study
to every year after.

  1. 01

    Site study

    Loads, utility tariff, roof and ground area, existing equipment and what independence means for you.

  2. 02

    DC-first design

    System architecture, equipment selection and drawings, PE-sealed where the jurisdiction requires it.

  3. 03

    Equipment & permits

    The full package specified and supplied, with documentation for permitting and interconnection.

  4. 04

    Installation

    Our licensed crews in Nevada; a coordinated licensed partner, or your own licensed installer, everywhere else.

  5. 05

    Programming & commissioning

    EMS configured for your site and tariff, then commissioned and acceptance-tested remotely.

  6. 06

    Monitoring & care

    Continuous monitoring, alerts, firmware, reporting and scheduled maintenance for the life of the system.

DELIVERY · A

Aeterna-installed

In states where Aeterna holds an electrical contractor license — Nevada first. Design, equipment, installation, programming and service from one team.

DELIVERY · B

Certified partner

A licensed local installer we select and coordinate does the field work under its own license. We provide design, equipment, programming, oversight and service.

DELIVERY · C

Your installer

Already have a licensed electrician or contractor? We supply the design, equipment, remote programming, controls and monitoring, and support them through the build.

E-701 Nationwide coverage

Headquartered in Nevada.
Built for all fifty.

Central engineering and controls. Local licensed hands.

One engineering and controls platform serves every state. Las Vegas is our headquarters and proving ground. From there, the planned rollout extends to high-value markets, then the Northeast and Midwest, then every remaining state through partners and client-selected installers.

  • Headquarters · Aeterna-installed
  • Phase 2 · high-value markets
  • Phase 3 · Northeast & Midwest
  • Phase 4 · all remaining states

Planned rollout; timing and partner availability vary by state.

E-801 About

Aeterna — from the Latin for eternal.

Aeterna Energy Group is a DC-first energy design, controls and service company headquartered in Las Vegas, Nevada. Our proprietary Aeterna DC-first system architecture is at the core of every project we deliver.

We are deliberately asset-light: we install with our own licensed electricians where we hold a license, and work through licensed installers everywhere else. That lets one design standard, one controls platform and one service organization stand behind every system, nationwide.

Headquarters
Las Vegas, Nevada
Focus
DC-first solar · storage · controls
Service area
United States

E-901 Consultation

Start with
a design consultation.

Tell us about the property. We'll tell you how far it can go.

Homeowners, builders, architects, property owners and installers are all welcome. Submitting opens an email to our team with your details filled in.

DIRECTinfo@aeternaenergygroup.com

Interested in